spa-and-hot-tub-error-codesThe best thing about digital spas and hot tubs – those with a spa side control panel – is that you are given error codes for most equipment problems. Spa error codes can be somewhat cryptic, but when you have the BIG LIST of CODES, you can immediately define the two or three digit source of trouble.

Problem is – there’s not much consistency among the error codes used by spa pack manufacturers. Each one uses it’s own conventions for naming the various system faults.

Hence the need for the BIG LIST of CODES. The alphabetical list of hot tub error codes below covers all major manufacturers of spa controls, including ACC, Balboa, Brett Aqualine, CTI, Dream Maker, EasyPak, Gecko, Hurricane, Jacuzzi, Len Gordon, Maax, Pinnacle, Spa Builders Group, Spa Quip, Sundance and Vita Spas.

Is it an Error Code, or a System Status Code?

Not all spa codes are errors, to inform you of trouble, but many codes are used to provide information about system mode, status or equipment operation. Some system status codes are identified below as well, with the phrase “system message, not an error”.

 

the big list of spa and hot tub error codes


CODE


ERROR CODE DESCRIPTION

* * *  Flow/Pressure switch either Open or Closed
* * * High Limit switch is faulty
– – – , – – – Water dangerously hot, electronic fault, system shut down
-1 Hi-Limit fault
-2 Temp sensor fault
-3 Flow/Pressure switch open
-4 Flow/Pressure switch closed
-7 Hi-Limit fault
Hi-Limit or Temp Sensor fault, water may be dangerously hot
Temp Sensor Calibration, after system shutdown/startup, not an error
1 Stuck Button on Keypad
2 No Controller Data being received
3 Temperature Sensor fault
4 Water Sensor/Pressure switch fault
5 Temp Sensor, or water is dangerously hot
6 High Limit manual reset on heater is tripped
7 Stuck Heater Relay
9 Water Pressure fault, pump may be airlocked, or water level low
131 Hi-Limit fault, water may be dangerously hot
A1/A2-ER Auxiliary system error; blower, lights, music
AOH Auxiliary system overheating; Equipment is running hot, or needs air
BJ2P Hi-Limit fault – water may be dangerously hot
BL-ER Blower error, faulty motor or closed valve
C4.4 Hi-Limit fault
C Celsius, used to indicate panel is in Celsius mode
Cd, CLd Cold – Freeze Condition detected
CE 01 Stuck Touchpad button
CE 02 No controller Data Communication
CE 03 Temperature Sensor fault
CE 04 Water Sensor/Pressure switch fault
CE 05 Temp Sensor, or water is dangerously hot
CE 06 High Limit manual reset on heater is tripped
CE 07 Stuck Heater Relay
CE 08 Temp Sensor Fault
CE 09 Water Pressure fault, pump may be airlocked, or water level low
CL Current Time of Day; system message, not an error
COL Cool – water is 20° below set point; system message, not an error
CoLd Cold – water is 40° or less; system should self-start pump / heater
Cool Cool – water is 20° below set point; system message, not an error
CP-ER Circulation pump error
dr, dy, dry Dry – low water volume detected in heater
E0 Short circuit temperature sensor
E1 Open circuit temperature sensor
E2 Short circuit Hi-Limit sensor
E3 Open circuit high Limit sensor
E4 Short circuit/closed pressure/flow switch
Ecdu, Ecn, Econ Spa is in Economy Mode; system message, not an error
EO Short circuit temperature sensor
Er0, Er1 Temperature sensor fault
Er2, Er3 Hi-Limit fault
Er4 Short circuit/closed pressure/flow switch
err 1 Water Pressure fault, pump may be airlocked, or water level low
err 3 Stuck Button on Keypad
err 4 Water Sensor/Pressure switch fault
err 5 Temp Sensor, or water is dangerously hot
err 6 High Limit manual reset on heater is tripped
err 7 Stuck Heater Relay
err 8 Temp Sensor Fault
Err Software Program Fault
Error 3 Stuck Button on Keypad
Error 4 Water Sensor/Pressure switch fault
Error 5 Temp Sensor, or water is dangerously hot
Error 6 High Limit manual reset on heater is tripped
Error 7 Stuck Heater Relay
Error 8 Temp Sensor Fault
F2 4 hours daily filtration; system message, not an error
F4 8 hours daily filtration; system message, not an error
F6 12 hours daily filtration; system message, not an error
F Fahrenheit, used to indicate panel is in Fahrenheit mode
FB-ER Fiber Optic error; accent lighting
FC Filter Continuous mode; system message, not an error
FL1 Water Pressure fault, dirty filter, airlocked pump, low water level
FL2 Pressure switch fault; switch closed while pump is off
FL Water Sensor/Pressure switch fault; water flow problem
FLC Pressure switch fault; switch closed while pump is off
Fldu Spa is in Filter mode; ; system message, not an error
FLO, Flo, FL1 Flow – inadequate water volume sensed by Flow / Pressure switch
FLO2 Flow – short circuit/closed circuit; pressure/flow switch
FLO (flashing) Flow – short circuit/open circuit; pressure/flow switch
Flon Spa is in Filter mode; ; system message, not an error
FN-ER Fan error; cooling fan fault
FP, Fr, FrE Freeze – water is 40° or less; system should self-start pump / heater
H2O Water Pressure fault, pump may be airlocked, or water level low
HFL Sensors out of balance, reporting different results
HiLi, HLEr Water temperature above acceptable range
HL, HH, OHH High limit sensor reading 118°, or above – check flow
Hold Panel buttons pressed to many times or too quickly
HOT Overheating, water over 112° F. Cool down procedure begins.
IC, ICE, ICE2 Freeze Condition detected; Warm up procedure begins.
ILOC Interlock failure; check magnetic contacts on spa equipment door
L1, L2 Panel Lock; enter code to unlock control panel
LF Persistent low flow problems.
LO Freeze Condition detected; Warm up procedure begins.
LOC Panel Lock; enter code to unlock control panel
O3-Er Ozone error; check for operation and output
OH High temperature condition, over 110ºF. Spa may be partially deactivated or low speed pump (and air blower if equipped) may activate to lower temp
OHH Overheat. One sensor has detected 118º. Spa has shut down
OHS Overheat. One sensor has detected 110º. Spa has shut down
OP Open circuit sensor
P1, P2 or P3-ER Pump 1,2 or 3 error or failure
pd Power supply interrupted, unit running on battery backup
PnL Panel error; communication error between panel and circuit board
Pr Priming – pump is starting; system message, not an error
Prh Hi-limit sensor failure
Prr Temperature Sensors Alarm
PS Water Sensor/Pressure switch fault
PSoC Pressure switch open on circulation
PSoH Pressure switch open on high speed
PSoL Pressure switch open on low speed
RH-HR Heater Repair error
RH-NC No Communication error; Panel to Board
RH-NF No Flow in heater
RH-NH No Heat, heater fault or failure
SA, SnA, SnH, Sb, Snb, Snt Sensor Open Circuit or faulty
SE Spa in Economy Mode; system message, not an error
SEoP Sensor open or disconnected. Heater disabled but spa operational
SESH Sensor short, nonfunctional. Heater disabled but spa operational
SH Short circuit on temperature sensor
Sn1 Hi-Limit fault, water may be dangerously hot
Sn2 Temperature sensor fault, Heater deactivated
Sn3 Temperature sensor fault, Heater deactivated
SN Temperature sensor fault, Heater deactivated
Sn Sensors out of balance, reporting different results
Sna Sensor plugged into jack A is not working. Spa is shut down.
Snb Sensor plugged into jack B is not working. Spa is shut down.
SnH Hi Limit circuit open or faulty
SnS Sensors out of balance, reporting different results
SnT Temperature sensor fault, circuit open or faulty
SP-F1,F2 or F3 Fuse 1,2 or blown
SP-HR Hardware error
SP-IN Input voltage low
SP-OH Overheat – water temp over 112°
SP-OT Overtemp – air temp around equipment is too hot, lack of air flow
Std Spa in Standard Mode; system message, not an error